The discovery that powers 95% of the world's electricity — with deep explanations, 20+ real-life examples, animated magnet-in-coil demos, interactive EMF simulator, exam traps and a printable formula sheet.
Before diving into individual sections, here's the entire chapter on one page. Use this as a mental map — every topic is a link in this chain.
Changing magnetic flux through a circuit induces an EMF (Faraday). The induced current opposes the change (Lenz) — energy is conserved. Motional EMF (Blv) is one important case. Coils resist changes in current (inductance). Everything from generators to wireless charging relies on this chain.
In 1831, Michael Faraday — a self-taught English scientist — made one of the most consequential discoveries in history: a changing magnetic field creates electricity. His simple experiments are worth understanding in detail.
A coil is connected to a galvanometer (a sensitive current detector). When you:
The key insight: it's the change in magnetic flux, not the magnetic field itself, that induces current. Static field = no current. Changing field = current.
Two coils (C₁ and C₂) are placed near each other. C₂ is connected to a battery through a switch. C₁ is connected to a galvanometer.
Again: change in one coil's current produces momentary current in the other. This is mutual induction.
One coil connected to a battery through a switch. When the switch is toggled, the coil itself resists the change in current — you can feel a spark or see a slow rise in current. This is self-induction.
Before Faraday, the only way to generate electricity was chemical batteries — expensive and low-power. Faraday's discovery showed that mechanical energy could be converted directly into electrical energy. Every power plant in the world today is based on this principle. It's no exaggeration to say Faraday's discovery made modern civilisation possible.
Faraday's experiments showed: a changing magnetic flux induces EMF. Static field → no current. Changing field → current. This is the foundation of all electricity generation.
Think of field lines as "arrows" filling space. Magnetic flux through a surface counts how many of these arrows pierce through it:
ΦB = B · A = B·A·cosθ
Where:
Unit: weber (Wb) = tesla × m² = T·m².
Φ is a scalar (dot product of two vectors). Positive or negative depending on direction.
Imagine holding a circular ring in a river. The "flux" of water through the ring is maximum when the ring is perpendicular to the flow, and zero when the ring is parallel to the flow (water just slides past). Same for magnetic flux — the "flow" is B-field, the "ring" is the surface.
Mistake: "Flux = B × A (no cosθ)."
Correction: Φ = BA cosθ — the angle between B and the normal to the surface matters. If B is parallel to the surface, θ = 90°, cosθ = 0, flux = 0. Always be careful about the angle!
Mistake: "Flux is a vector."
Correction: Flux is a scalar (dot product of two vectors). It has a magnitude and a sign (+ or −), but no direction in space.
Φ = B·A·cosθ. Unit: weber (Wb). Max when B ⊥ surface, zero when B ∥ surface. It's a scalar. Flux is what Faraday's experiments change — induced EMF depends on the rate of change of flux, not the flux itself.
Faraday summarised his experiments in a beautifully simple law:
ε = −N · dΦB/dt
Where:
For a single loop (N=1): ε = −dΦ/dt
A coil with N turns is like N separate loops, each contributing its own induced EMF. Since they're in series, the EMFs add. So doubling N doubles the EMF. This is why generators and transformers use many-turn coils — more turns = more voltage.
Mistake: "EMF depends on the flux Φ."
Correction: EMF depends on the rate of change dΦ/dt. A static flux — even a very large one — induces no EMF. That's why a magnet sitting inside a coil produces no current. Only a changing flux induces EMF.
Mistake: "The negative sign is just a convention."
Correction: The negative sign has physical meaning: it's Lenz's law, which ensures energy conservation. If the induced EMF assisted the change, you'd get infinite energy — impossible. The negative sign is essential physics.
Faraday's law: ε = −N dΦ/dt. The EMF depends on the rate of change of flux, not the flux itself. More turns = more EMF. The negative sign (Lenz) is essential for energy conservation.
Lenz's law tells you which direction the induced current flows. It's the physical reason for the minus sign in Faraday's law:
The induced current always flows in a direction that opposes the change in flux that produced it.
More precisely:
Imagine a self-closing door. Push to open it — it pushes back. That's Lenz's law: any change in flux is "pushed back" by an induced current. It's like a natural "inertia" that resists changes in magnetic state.
Suppose the induced current assisted the change instead of opposing it. Then you'd push the magnet toward the coil a tiny bit, and the coil would "help" by attracting the magnet faster → it would accelerate on its own → free energy. That would violate the conservation of energy.
So the induced current must oppose the motion. The work you do against this opposition becomes the electrical energy. That's why Faraday's law has a negative sign — it encodes energy conservation.
Trap: "The induced current is always in the direction of the external field."
Correction: No! It's the opposite. If the external field is increasing, the induced current creates a field opposing the external field. If the external field is decreasing, the induced current creates a field supporting the external field. Always ask: is flux increasing or decreasing?
Lenz's law: induced current opposes the change in flux. If flux increases, current reduces it. If flux decreases, current supports it. This is essential for energy conservation. Explains eddy current braking, magnetic damping, and why the negative sign is in Faraday's law.
The most important special case: a conducting rod moving through a uniform magnetic field. This is how most generators work.
A rod of length L moving with speed v perpendicular to a uniform magnetic field B has an induced EMF between its ends:
ε = B·L·v
Direction: given by the right-hand rule (or Lenz's law).
| Approach | Reasoning |
|---|---|
| Faraday's law | As the rod slides, it sweeps out area. Flux through the circuit changes at rate dΦ/dt = B·L·v. So EMF = BLv. |
| Lorentz force | Free charges in the moving rod feel magnetic force qvB along the rod. This "separation" of charge creates an EMF = BLv (work per unit charge). |
Both approaches give the same result — beautiful physics!
If the rod completes a circuit of resistance R:
I = BLv/R
Force needed to keep it moving: F = BIL = B²L²v/R (opposing the motion — Lenz!)
Power dissipated: P = F·v = B²L²v²/R = I²R = ε²/R ✓
This is exactly the electrical power dissipated as heat in R. The mechanical work you do (F·v) converts to electrical energy. Perfect energy bookkeeping!
Mistake: "EMF = BLv works for any motion."
Correction: The formula BLv applies only when v is perpendicular to B. If v has a component along B, only the perpendicular component contributes. More generally: ε = B·(v × L) applied component-wise.
Mistake: "A moving wire always has induced current."
Correction: There's EMF if the wire moves in a field — but current only flows if the wire forms a closed circuit. An open wire has EMF but no current.
Motional EMF: ε = BLv (when v ⊥ B). Current I = BLv/R. Force needed F = B²L²v/R. Power = F·v = I²R. This is the fundamental equation for generators and dynamic microphones. Energy bookkeeping always works out (mechanical work → electricity).
When a solid piece of metal is exposed to a changing magnetic flux, eddy currents flow in swirling loops within the metal. These are induced currents — just like in a wire, but spread across the bulk.
Circular electric currents induced in a bulk conductor when it's exposed to a changing magnetic field.
Direction: by Lenz's law — always opposes the change that produced them.
Effects: heat generation, magnetic damping, energy loss in transformers.
Useful: They enable contactless braking, induction heating, metal detection — no mechanical wear, no sparks, very clean.
Problematic: In motors, transformers, and generators, they cause energy loss as heat — reducing efficiency. That's why transformer cores are laminated (thin sheets with insulation between them, so eddy currents can't flow large loops).
A solid iron core would have low resistance, letting eddy currents flow freely and heat up the core. Laminating it (stacking thin insulated sheets) forces eddy currents into tiny loops within each sheet, drastically reducing their magnitude (resistance ∝ length, so smaller loops = higher resistance = less current = less heating). This one invention allowed efficient AC transformers and made long-distance power transmission viable.
Eddy currents = induced currents in bulk conductors. Oppose changes (Lenz). Cause heating and magnetic drag. Useful: brakes, induction cooking, metal detectors. Problematic: transformer/motor losses → solved by lamination.
Just as mass resists changes in velocity, inductance resists changes in current. When current through a coil changes, the coil's own magnetic flux changes, inducing an EMF that opposes the change.
Φtotal = L·I (total flux linkage)
ε = −L·dI/dt
Unit: henry (H) = Wb/A = V·s/A.
L depends only on geometry and core material — like capacitance depends on geometry.
Two coils close together. Current I₂ in coil 2 creates flux Φ₁ through coil 1:
N₁Φ₁ = M·I₂
ε₁ = −M·dI₂/dt
Unit: henry. M depends on geometry and separation of the two coils. M₁₂ = M₂₁ (a deep reciprocity property).
| Quantity | Formula | Note |
|---|---|---|
| Self-inductance L | L = μ₀n²Aℓ = μ₀N²A/ℓ | n = N/ℓ (turns/m) |
| With core (μ_r) | L = μ_rμ₀n²Aℓ | Iron core multiplies L by μ_r |
| Mutual inductance (two coaxial) | M = μ₀n₁n₂πr₁²ℓ | r₁ = inner solenoid radius |
Think of current as water in a pipe, and inductance as the "inertia" of the water. When you suddenly stop the flow (open a valve), the moving water keeps going, creating a pressure spike ("water hammer"). That's exactly what an inductor does — when you try to interrupt the current, it produces a large back-EMF. That's why a spark appears when you unplug an inductive load.
Trap: "L depends on the current through the coil."
Correction: L depends ONLY on geometry (turns, area, length) and core material (μ_r). It's like how capacitance C depends on geometry, not on the charge. Changing I changes the flux and EMF, but NOT L itself.
Self-inductance: ε = −L dI/dt. Mutual: ε₁ = −M dI₂/dt. L = μ₀n²Aℓ for a solenoid. L and M depend only on geometry, not current. Inductors resist changes in current — like inertia for electrons. Basis of transformers, wireless charging, ignition coils.
To establish a current in an inductor, you have to do work against its back-EMF. That work is stored as magnetic potential energy in the field.
U = ½ L I²
This is the magnetic analog of ½CV² for a capacitor or ½mv² for kinetic energy.
uB = B² / (2μ₀)
Units: J/m³. This is the "energy per unit volume" stored in the magnetic field itself, anywhere in space.
Energy in an inductor: U = ½LI². Energy density: u = B²/(2μ₀). Magnetic analog of capacitor's ½CV². Stored in the magnetic field. Basis of switch-mode power supplies, energy storage, and flash circuits.
The AC generator (alternator) is a coil rotating in a magnetic field. As the coil turns, the flux through it changes sinusoidally — inducing an oscillating EMF. This is the device that produces virtually all the world's electricity.
A coil of N turns, area A, rotating with angular speed ω in a uniform field B:
Flux: Φ(t) = B·A·cos(ωt)
Induced EMF: ε(t) = N·B·A·ω·sin(ωt)
Peak EMF: ε₀ = NBAω
Frequency: f = ω/(2π) = rotations per second
Because the flux through the coil depends on cos(ωt) — as the coil rotates, the angle between B and the coil's normal changes sinusoidally. The rate of change of flux is then sin(ωt). When the coil is perpendicular to B (θ = 0), flux is maximum but its rate of change is zero → EMF is zero. When the coil is parallel to B (θ = 90°), flux is zero but changing fastest → EMF is maximum. That's why EMF and flux are 90° out of phase.
AC generator: ε = NBAω sin(ωt). Peak EMF = NBAω. Frequency = ω/2π. All power plants use this principle — the only thing that differs is what spins the rotor (water, steam, wind, gas). RMS voltage = peak/√2.
Q1. A magnetic field of 0.4 T is perpendicular to a coil of area 0.05 m². Find the flux through the coil.
B = 0.4 T, A = 0.05 m², θ = 0° (perpendicular)
Φ = BA cosθ
Φ = 0.4 × 0.05 × cos(0°) = 0.4 × 0.05 × 1 = 0.02 Wb
Q2. The magnetic flux through a coil of 100 turns changes from 0.05 Wb to 0.01 Wb in 0.2 s. Find the average induced EMF.
N = 100, Φ₁ = 0.05 Wb, Φ₂ = 0.01 Wb, Δt = 0.2 s
ΔΦ = 0.01 − 0.05 = −0.04 Wb
|ε| = N |ΔΦ/Δt| = 100 × (0.04/0.2)
|ε| = 100 × 0.2 = 20 V
Q3. A rod of length 0.5 m moves with speed 4 m/s perpendicular to a field of 0.2 T. Find the motional EMF. If the circuit resistance is 0.4 Ω, find the current and force needed to maintain motion.
L = 0.5 m, v = 4 m/s, B = 0.2 T, R = 0.4 Ω
ε = BLv = 0.2 × 0.5 × 4 = 0.4 V
I = ε/R = 0.4/0.4 = 1 A
F = BIL = 0.2 × 1 × 0.5 = 0.1 N
Direction: opposite to motion (Lenz's law)
Q4. A solenoid of 1000 turns, area 0.02 m², and length 0.5 m carries a current of 2 A. Find its self-inductance and stored energy.
N = 1000, A = 0.02 m², ℓ = 0.5 m, I = 2 A
L = μ₀N²A/ℓ = (4π×10⁻⁷ × 10⁶ × 0.02)/0.5
= (4π×10⁻⁷ × 20000)/0.5 = 8π×10⁻⁷/0.5
= 16π×10⁻⁷ ≈ 5.03 × 10⁻⁶ H = 5.03 μH
U = ½LI² = ½ × 5.03×10⁻⁶ × 4
= 1.01 × 10⁻⁵ J
Tiny energy — inductors store much less than capacitors of comparable size. Superconducting coils can store MWh!
Q5. A coil of area 0.1 m² and 500 turns rotates at 60 rev/s in a 0.2 T field. Find the peak EMF.
N = 500, A = 0.1 m², f = 60 Hz → ω = 2π×60 = 377 rad/s, B = 0.2 T
ε₀ = NBAω
ε₀ = 500 × 0.2 × 0.1 × 377
= 500 × 0.02 × 377
= 10 × 377
= 3770 V
ε_rms = ε₀/√2 ≈ 3770/1.414 ≈ 2666 V ≈ 2.7 kV
Q6. A magnet is dropped through a vertical copper tube. Explain what happens using Lenz's law. What happens if the tube is made of plastic?
As the magnet falls, the flux through each "ring" of copper changes. By Faraday's law, EMF is induced; by Lenz's law, eddy currents flow that oppose the magnet's motion (upward force). The magnet reaches terminal velocity when magnetic drag = weight. It falls slowly.
No free electrons → no eddy currents → no magnetic drag. The magnet falls freely (acceleration = g).
This is a classic classroom experiment. A neodymium magnet dropped through a 1m copper tube takes ~10 seconds to fall instead of ~0.45 seconds in free fall. The energy goes into heating the copper.
Q7. Two coils have a mutual inductance of 0.5 H. If the current in one changes from 2 A to 6 A in 0.1 s, what is the EMF induced in the other?
M = 0.5 H, ΔI = 6 − 2 = 4 A, Δt = 0.1 s
|ε| = M · |ΔI/Δt|
|ε| = 0.5 × (4/0.1) = 0.5 × 40 = 20 V
By Lenz's law, the induced EMF in the second coil opposes the increase in current in the first.
| Φ | Magnetic flux (weber, Wb) |
| ε | Induced EMF (volt, V) |
| N | Number of turns |
| L | Self-inductance (henry, H) |
| M | Mutual inductance (H) |
| B | Magnetic field (tesla, T) |
| A | Area (m²) |
| θ | Angle between B and area normal |
| v | Velocity (m/s) |
| ℓ | Length of conductor / solenoid (m) |
| n | Turns per unit length = N/ℓ |
| ω | Angular frequency (rad/s) |
| μ₀ | Permeability of free space = 4π×10⁻⁷ |
| μ_r | Relative permeability |
(A) Both true, R explains A. (B) Both true, R does NOT explain A. (C) A true, R false. (D) A false, R true.